WEKO3
アイテム
{"_buckets": {"deposit": "4780cf85-fa76-4095-8055-3348ff6d24ff"}, "_deposit": {"created_by": 11, "id": "143", "owners": [11], "pid": {"revision_id": 0, "type": "depid", "value": "143"}, "status": "published"}, "_oai": {"id": "oai:yachts.repo.nii.ac.jp:00000143", "sets": ["52"]}, "author_link": ["2353", "2356", "2354", "2351", "2352", "2355"], "item_2_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "91", "bibliographicPageStart": "87", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "山形保健医療研究"}]}]}, "item_2_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "山形県クロスカントリースキー・ジュニア強化選手を対象に再呼吸法による心拍出量測定(Q)を行った.運動負荷はトレッドミルを使用し,最大運動に至るまで漸増負荷を行った.再呼吸法によるQ測定は10〜20秒の時間を要するために,最大運動時のQを正確に得ることは困難である.最大運動以下の運動定常状態で測定したQと運動強度との回帰式から最大運動強度に補外したQ(補外値Q)を求めた.実測のQは,補外値Qの約50%であった.最大運動に達する迄の酸素摂取量と心拍数から求めた酸素脈を解析することにより最大運動時のQ(推定値Q)を推定した.補外値Qは,推定値Qの約60%であった.酸素脈から推定したQに比べ実測値Q及び補外値Qは,有意に低かった.酸素脈から推定したQは,最大運動時まで実測できる酸素摂取量及び心拍数を用いているので,最大運動時のQの推定値として妥当なものと考えられる", "subitem_description_type": "Abstract"}]}, "item_2_relation_29": {"attribute_name": "医中誌ID", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "1999238798", "subitem_relation_type_select": "ICHUSHI"}}]}, "item_2_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-876X", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大森, 圭"}], "nameIdentifiers": [{"nameIdentifier": "2351", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "古川, 順光"}], "nameIdentifiers": [{"nameIdentifier": "2352", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉野, 直美"}], "nameIdentifiers": [{"nameIdentifier": "2353", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮下, 智"}], "nameIdentifiers": [{"nameIdentifier": "2354", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "内田, 勝雄"}], "nameIdentifiers": [{"nameIdentifier": "2355", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "丹羽, 健市"}], "nameIdentifiers": [{"nameIdentifier": "2356", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-11-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "99.15.pdf", "filesize": [{"value": "1.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1600000.0, "url": {"label": "99.15", "url": "https://yachts.repo.nii.ac.jp/record/143/files/99.15.pdf"}, "version_id": "bf132f2a-cd1b-496b-a601-ca8797c4b2b8"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "運動負荷試験", "subitem_subject_scheme": "Other"}, {"subitem_subject": "酸素消費", "subitem_subject_scheme": "Other"}, {"subitem_subject": "心拍出量", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒト", "subitem_subject_scheme": "Other"}, {"subitem_subject": "男", "subitem_subject_scheme": "Other"}, {"subitem_subject": "女", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "酸素脈を用いた最大運動時の心拍出量の推定", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "酸素脈を用いた最大運動時の心拍出量の推定"}, {"subitem_title": "Estimation ofthe Cardiac Output at Exhaustion from Oxygen Pulse", "subitem_title_language": "en"}]}, "item_type_id": "2", "owner": "11", "path": ["52"], "permalink_uri": "https://yachts.repo.nii.ac.jp/records/143", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-11-08"}, "publish_date": "2016-11-08", "publish_status": "0", "recid": "143", "relation": {}, "relation_version_is_last": true, "title": ["酸素脈を用いた最大運動時の心拍出量の推定"], "weko_shared_id": -1}
酸素脈を用いた最大運動時の心拍出量の推定
https://yachts.repo.nii.ac.jp/records/143
https://yachts.repo.nii.ac.jp/records/143d460bff1-2797-4ed2-bf60-37feb76f5f6a
名前 / ファイル | ライセンス | アクション |
---|---|---|
99.15 (1.6 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-11-08 | |||||
タイトル | ||||||
タイトル | 酸素脈を用いた最大運動時の心拍出量の推定 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Estimation ofthe Cardiac Output at Exhaustion from Oxygen Pulse | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 運動負荷試験 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 酸素消費 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 心拍出量 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ヒト | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 男 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 女 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
大森, 圭
× 大森, 圭× 古川, 順光× 吉野, 直美× 宮下, 智× 内田, 勝雄× 丹羽, 健市 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 山形県クロスカントリースキー・ジュニア強化選手を対象に再呼吸法による心拍出量測定(Q)を行った.運動負荷はトレッドミルを使用し,最大運動に至るまで漸増負荷を行った.再呼吸法によるQ測定は10〜20秒の時間を要するために,最大運動時のQを正確に得ることは困難である.最大運動以下の運動定常状態で測定したQと運動強度との回帰式から最大運動強度に補外したQ(補外値Q)を求めた.実測のQは,補外値Qの約50%であった.最大運動に達する迄の酸素摂取量と心拍数から求めた酸素脈を解析することにより最大運動時のQ(推定値Q)を推定した.補外値Qは,推定値Qの約60%であった.酸素脈から推定したQに比べ実測値Q及び補外値Qは,有意に低かった.酸素脈から推定したQは,最大運動時まで実測できる酸素摂取量及び心拍数を用いているので,最大運動時のQの推定値として妥当なものと考えられる | |||||
書誌情報 |
山形保健医療研究 巻 2, p. 87-91, 発行日 1999-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-876X | |||||
医中誌ID | ||||||
識別子タイプ | ICHUSHI | |||||
関連識別子 | 1999238798 |