{"created":"2023-05-15T08:55:12.054168+00:00","id":109,"links":{},"metadata":{"_buckets":{"deposit":"65004e74-02ab-4661-b7a2-70f60ad100b8"},"_deposit":{"created_by":11,"id":"109","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"109"},"status":"published"},"_oai":{"id":"oai:yachts.repo.nii.ac.jp:00000109","sets":["6:29:47"]},"author_link":["2151","2150","2149","2154","2153","2148","2152"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"56","bibliographicPageStart":"51","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"山形保健医療研究"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"等速性筋力測定装置Cybex770-NORMから出力されるデータを検証する目的で,健常成人20名を対象に,最大努力での膝関節屈曲伸展運動を行った.本装置に外部インターフェイスとBIMUTASを接続してアナログデータを採取し,デジタル信号によるCybexデータと比較した.角速度設定は450deg/secとした.Cybexデータの°ークトルク(PT)発輝時の角速度は全て等速性運動域に到達していなかった.CybexデータのPT値と,これに対応するアナログデータのトルク値は有意な高い相関を示した.しかし,Cybexデータはアナログデータに比し有意に低値を示した.本研究結果より,本装置からは等速性運動域に到達しなくてもPT値が出力去れると共に,アナログデータとの相違点を有することが示された.本装置を使用する場合には,アナログデータを考慮する必要性があるものと考えられた","subitem_description_type":"Abstract"}]},"item_2_relation_29":{"attribute_name":"医中誌ID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2002218515","subitem_relation_type_select":"ICHUSHI"}}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1343-876X","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉野, 直美"}],"nameIdentifiers":[{"nameIdentifier":"2148","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三和, 真人"}],"nameIdentifiers":[{"nameIdentifier":"2149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 克彦"}],"nameIdentifiers":[{"nameIdentifier":"2150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮崎, 純弥"}],"nameIdentifiers":[{"nameIdentifier":"2151","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小野, 武也"}],"nameIdentifiers":[{"nameIdentifier":"2152","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"百瀬, 公人"}],"nameIdentifiers":[{"nameIdentifier":"2153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊橋, 光二"}],"nameIdentifiers":[{"nameIdentifier":"2154","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-07"}],"displaytype":"detail","filename":"2002.08.pdf","filesize":[{"value":"1.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2002.08","url":"https://yachts.repo.nii.ac.jp/record/109/files/2002.08.pdf"},"version_id":"57eb3a97-07d5-48a5-a73f-35de900ed291"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"労作","subitem_subject_scheme":"Other"},{"subitem_subject":"筋骨格系生理学的現象","subitem_subject_scheme":"Other"},{"subitem_subject":"身体運動","subitem_subject_scheme":"Other"},{"subitem_subject":"理学的検査","subitem_subject_scheme":"Other"},{"subitem_subject":"トルク","subitem_subject_scheme":"Other"},{"subitem_subject":"筋力","subitem_subject_scheme":"Other"},{"subitem_subject":"測定機器","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_scheme":"Other"},{"subitem_subject":"男","subitem_subject_scheme":"Other"},{"subitem_subject":"女","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"等速性筋力測定装置Cybexの運動角速度の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"等速性筋力測定装置Cybexの運動角速度の検証"},{"subitem_title":"Verification of angular verlocity by Cybex 770-NORM","subitem_title_language":"en"}]},"item_type_id":"2","owner":"11","path":["47"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-11-07"},"publish_date":"2016-11-07","publish_status":"0","recid":"109","relation_version_is_last":true,"title":["等速性筋力測定装置Cybexの運動角速度の検証"],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2023-05-15T09:11:01.953835+00:00"}