{"created":"2023-05-15T08:55:11.917373+00:00","id":106,"links":{},"metadata":{"_buckets":{"deposit":"3565f88f-9a31-4877-a62e-df974771a36d"},"_deposit":{"created_by":11,"id":"106","owners":[11],"pid":{"revision_id":0,"type":"depid","value":"106"},"status":"published"},"_oai":{"id":"oai:yachts.repo.nii.ac.jp:00000106","sets":["6:29:47"]},"author_link":["2133","2132","2135","2134","2131","2136"],"item_2_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"35","bibliographicPageStart":"31","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"山形保健医療研究"}]}]},"item_2_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"山形県立保健医療大学及びUniversity of Colorado Health Science Center rehabilitation Medicine,Physical Therapy Program所有の三次元動作解析装置によって得られるデータの精度を検討した.測定は両大学において正三角形のアルミフレームを回転台に固定し,静止時と回転時にアルミフレームの3個所に貼り付けた反射マーカーによって成す角度を計測することで行った.その結果,両大学とも十分に信頼性のある測定が可能であったことから,データに互換性があることが示された.今後,両大学における共同研究が期待できるものと思われた","subitem_description_type":"Abstract"}]},"item_2_relation_29":{"attribute_name":"医中誌ID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2002215062","subitem_relation_type_select":"ICHUSHI"}}]},"item_2_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1343-876X","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小野, 武也"}],"nameIdentifiers":[{"nameIdentifier":"2131","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉野, 直美"}],"nameIdentifiers":[{"nameIdentifier":"2132","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮崎, 純弥"}],"nameIdentifiers":[{"nameIdentifier":"2133","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 克彦"}],"nameIdentifiers":[{"nameIdentifier":"2134","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"駒沢, 治夫"}],"nameIdentifiers":[{"nameIdentifier":"2135","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊橋, 光二"}],"nameIdentifiers":[{"nameIdentifier":"2136","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-07"}],"displaytype":"detail","filename":"2002.05.pdf","filesize":[{"value":"1.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2002.05","url":"https://yachts.repo.nii.ac.jp/record/106/files/2002.05.pdf"},"version_id":"036893cd-d4c0-4583-961c-52bc1f99c94b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"運動障害(診断)","subitem_subject_scheme":"Other"},{"subitem_subject":"機器と資材用品","subitem_subject_scheme":"Other"},{"subitem_subject":"大学","subitem_subject_scheme":"Other"},{"subitem_subject":"動作","subitem_subject_scheme":"Other"},{"subitem_subject":"理学療法","subitem_subject_scheme":"Other"},{"subitem_subject":"三次元","subitem_subject_scheme":"Other"},{"subitem_subject":"測定機器","subitem_subject_scheme":"Other"},{"subitem_subject":"動作分析","subitem_subject_scheme":"Other"},{"subitem_subject":"測定精度","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"コロラド大学と当大学における三次元動作解析装置精度の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"コロラド大学と当大学における三次元動作解析装置精度の検討"},{"subitem_title":"The reliability of the three-dimensional motion analysis system in the University of Colorado Health Science Center,Rehabilitation Medicine,Physical Therapy Program and Yamagata Prefectural University of Health Science.","subitem_title_language":"en"}]},"item_type_id":"2","owner":"11","path":["47"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-11-07"},"publish_date":"2016-11-07","publish_status":"0","recid":"106","relation_version_is_last":true,"title":["コロラド大学と当大学における三次元動作解析装置精度の検討"],"weko_creator_id":"11","weko_shared_id":-1},"updated":"2023-05-15T09:11:22.316469+00:00"}